Manual No. 91000116-001 Revision B October 15, 2002 The MegaPlusâ Model ES 4.0/E Camera User’s Manual Redlake MASD, Inc. 11633 So
REDLAKE MASD, INC. Figure 2-3A. Rear Panel (CameraLink) Figure 2-3B. Rear Panel (RS422/LVDS) 2.2 Camera Rear Panel 2.2.1 Digital Interface The
MegaPlus® Model ES 4.0/E 2.3 Cables There are three different cables available to connect the MegaPlus Camera to your computer, as shown in Figure 2-5
REDLAKE MASD, INC. 2.4 Hardware Setup Follow the instructions supplied by the frame grabber manufacturer when you are using their cables to install yo
MegaPlus® Model ES 4.0/E 2.5 Routine Maintenance There are no user serviceable parts inside the camera. The camera must be returned to the factory f
REDLAKE MASD, INC. THIS PAGE INTENTIONALLY LEFT BLANK 91000116-001 Revision B 2-6 10/15/02
MegaPlus® Model ES 4.0/E 3. CAMERA OPERATION 3.1 Introduction The MegaPlus camera, Model ES 4.0/E, does not have any manual controls on the camera it
REDLAKE MASD, INC. The camera will recognize a command as three command characters, followed by a space character (or “?” in the case of a query), fol
MegaPlus® Model ES 4.0/E 3.4.4 Continuous Fluoroscopy This mode is similar to the Continuous mode, except that the electronic shutter is not used. T
REDLAKE MASD, INC. 3.4.8 Mode Use this command to set the camera mode of operation. TYPE IN: RESPONSE EXPLANATION MDE CS CR-LF Sets the mode to c
MegaPlus® Model ES 4.0/E TYPE IN RESPONSE RDM=2 BNS=3 RDM=2 BNS=2 RDM=2 BNS=1 RDM=1 BNS=3 RDM=1 BNS=2 RDM=1 BNS=1 FRS 60 CR-LF 60 fps/ 20 MHz ** ** *
REDLAKE MASD, INC. List of Manual Revisions User’s Manual – Model ES 4.0/E, Part Number 91000116-001 Revision Date EO No. Notes A 07-15-02 Ini
REDLAKE MASD, INC. TRM P (see *NOTE) CR-LF A positive going edge at the AIA EXPOSE input trigger connector will start an exposure. TRM N (See *NOTE)
MegaPlus® Model ES 4.0/E 3.4.15 Pixel-by-Pixel Corrector The camera has offset and gain coefficients stored for every active pixel in the sensor. Wh
REDLAKE MASD, INC. 3.4.19 Alternate Correction Table This command allows the user to select either the standard or the alternate Offset and Gain Cor
MegaPlus® Model ES 4.0/E 3.4.23 Reset This command allows you to recall saved (SAV) settings. RST 3, for example, recalls the settings saved when yo
REDLAKE MASD, INC. 3.4.26 PSC Command This command enables or disables the continuous background checks on the fan, Thermoelectric Cooling (TEC), and
MegaPlus® Model ES 4.0/E 3.5 Query Commands 3.5.1 Temperature Query This command queries the temperature sensor on the Processor Board. TYPE IN: RE
REDLAKE MASD, INC. 3.6 Alphabetical Command Summary NOTE: The commands listed below can be entered in either upper or lower case. FUNCTION COMM
MegaPlus® Model ES 4.0/E 4. INTERFACE SPECIFICATIONS 4.1 Introduction Chapter Four gives you the information needed to interface the MegaPlus Camera,
REDLAKE MASD, INC. Table 4-1. Digital Interface Connector Pin Out (on rear of camera) PIN SIGNAL NAME PIN SIGNAL NAME SOURCE 1 GROUND 35 GROUND
MegaPlus® Model ES 4.0/E Table 4-2. 68-Pin Interface Cable*, With 9-Pin RS232 Cable PIN SIGNAL NAME PIN SIGNAL NAME SOURCE 1 GROUND 35 GROUND Bo
MegaPlus® Model ES 4.0/E PRECAUTIONS WARNING! LIFE SUPPORT APPLICATIONS POLICY MegaPlus cameras are not authorized for and should not
REDLAKE MASD, INC. Table 4-3. 26-Pin Camera Link Cable Pinout PIN SIGNAL NAME PIN SIGNAL NAME SOURCE 1 IN SHLD GND 14 IN SHLD GND Both 2 X0
MegaPlus® Model ES 4.0/E 4.7 Timing Waveforms Figure 4-2. Continuous Mode – Variable Exposure Timing Figure 4-3. Continuous Mode – Variable Exposu
REDLAKE MASD, INC. Figure 4-6. Double Image Mode Timing Figure 4-7. Controlled Mode Timing Figure 4-8. Line Timing 91000116-001 Revision B 4
MegaPlus® Model ES 4.0/E 4.8 Specifications 4.8.1 Video Performance Black Level: Clamped to black reference at the start of each frame. Gamma:
REDLAKE MASD, INC. 4.9 C-Mount Camera Dimensions NOTE: Dimensions contained in brackets, [xx.x], are in millimeters. Other dimensions are in inches
MegaPlus® Model ES 4.0/E NOTE: Dimensions contained in brackets, [xx.x], are in millimeters. Other dimensions are in inches. Figure 4-10. C-
REDLAKE MASD, INC. 4.10 F-Mount Camera Dimensions NOTE: Dimensions contained in brackets, [xx.x], are in millimeters. Other dimensions are in inche
MegaPlus® Model ES 4.0/E NOTE: Dimensions contained in brackets, [xx.x], are in millimeters. Other dimensions are in inches. Figure 4-12. F-
REDLAKE MASD, INC. THIS PAGE INTENTIONALLY LEFT BLANK 91000116-001 Revision B 4-12 10/15/02
MegaPlus® Model ES 4.0/E APPENDIX A – ERROR CODES AND DESCRIPTIONS Code Name Description ERROR_NONE 01 ERROR_SYNTAX Bad command 02 ERROR_XMIT
REDLAKE MASD, INC. TABLE OF CONTENTS 1. INTRODUCTION...
REDLAKE MASD, INC. THIS PAGE INTENTIONALLY LEFT BLANK 91000116-001 Revision B II 10/15/02
MegaPlus® Model ES 4.0/E 3.5.1 Temperature Query... 3-11
REDLAKE MASD, INC. THIS PAGE INTENTIONALLY LEFT BLANK 91000116-001 Revision B vi 10/15/02
MegaPlus® Model ES 4.0/E 1. INTRODUCTION 1.1 Introduction With spatial resolution of four million pixels, and several different frame rates achieved t
REDLAKE MASD, INC. LIMITED WARRANTY For a period of one (1) year from the date of shipment, the Redlake Product and any Redlake manufactured access
MegaPlus® Model ES 4.0/E 2. CONTROLS AND CONNECTORS 2.1 Camera NOTE: A lens cap is installed on each camera to keep dust from getting on the optica